Virtuoso AMS Environment User Guide

Variables for ams.env Files

wfDefInstSaveCurrents

Controls whether current probes are created for the objects selected from the schematic or the navigator.

Syntax

amsDirect.prep wfDefInstSaveCurrents boolean t | nil

Values

 

t

Places a checkmark next to the Currents at terminals or ports

 

label in the Waveforms pane of the AMS Options window,

 

indicating that current probes are to be created for the objects

 

selected from the schematic or the navigator.

nil

Removes the checkmark next to the Currents at terminals or

 

ports label in the Waveforms pane of the AMS Options window,

 

indicating that current probes are not to be created. This is the

 

default.

Example

amsDirect.prep wfDefInstSaveCurrents boolean t

Places a checkmark next to the Currents at terminals or port labels, indicating that current probes are to be created for objects selected from the schematic or the navigator.

April 2004

580

Product Version 5.3

Virtuoso AMS Environment User Guide

Variables for ams.env Files

wfDefInstSaveVoltages

Controls whether voltage probes are created for instances selected from the schematic or the navigator.

Syntax

amsDirect.prep wfDefInstSaveVoltages boolean t | nil

Values

 

t

Places a checkmark next to the Voltages/Signals label in the

 

Waveforms pane of the AMS Options window, indicating that

 

voltage probes are to be created for instances selected from the

 

schematic or navigator. This is the default.

nil

Removes the checkmark next to the Voltages/Signals field in

 

the Waveforms pane of the AMS Options window, indicating

 

that voltages are not to be created for instances selected from

 

the schematic or navigator.

Example

amsDirect.prep wfDefInstSaveVoltages boolean nil

Removes the checkmark next to the Voltages/Signals label so voltage probes are not created for objects selected from the schematic or navigator.

April 2004

581

Product Version 5.3

Virtuoso AMS Environment User Guide

Variables for ams.env Files

wfDefInstVSaveAll

Specifies whether voltage probes are to be created for all levels of the instances selected from the schematic or the navigator.

Syntax

amsDirect.prep wfDefInstVSaveAll t | nil

Values

 

t

Specifies that voltage probes are to be created for all levels of the

 

selected instances. This choice is indicated in the AMS Save/

 

Plot list by the word all appearing in the Depth column for the

 

selected instances

nil

Specifies that voltage probes for the selected instances are to be

 

created only for the number of levels specified by the

 

amsDirect.prep wfDefInstVSaveLvl variable. This is the

 

default.

Example

amsDirect.prep wfDefInstVSaveAll nil

Specifies that voltage probes are to be created for all levels of the selected instances.

April 2004

582

Product Version 5.3

Virtuoso AMS Environment User Guide

Variables for ams.env Files

wfDefInstVSaveLvl

Specifies that voltage probes for the specified number of levels are to be created for instances selected from the schematic or the navigator.

Syntax

amsDirect.prep wfDefInstVSaveLvl int level

Values

 

level

The number of levels of voltage probes to be created for the

 

selected instances. The default value is 1.

Example

amsDirect.prep wfDefInstVSaveLvl int 2

Specifies that voltage probes are to be created for two levels of each of the selected instances. In the AMS Save/Plot list, the Depth column for the selected instances contains the value 2.