Appendix B: Hub Requests

0 = No change has occurred to the over-current status indicator

1 = The over-current indicator has changed

This change bit tells software that there has been a change in the over-current status and the over-current indicator bit should be checked to determine the current state of the current limiter logic. (e.g., power has been removed to all ports due to the over-current condition.)

Table B-6: Format of Hub Change Field Returned During the Get Hub Status Request

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Over-

Local

 

 

Reserved (returns zero)

 

 

Current

Power

 

 

 

 

 

 

Indicator

Status

 

 

 

 

 

 

Change

Change

 

 

 

 

 

 

 

 

15

14

13

12

11

10

9

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved (returns zero)

 

 

 

 

 

 

 

 

 

 

 

Set/Clear Hub Feature Request

The hub class definition of the “Set Feature” and “Clear Feature” requests depends on the value of the feature selector byte. The selector byte defines the hub-specific feature that is to be either set or cleared. These features globally apply to the hub; therefore, the “index” field of the setup transaction is 00h for hub features. Table B-7 lists the hub features defined for hub class requests.

Table B-7: Feature Selector and Index Values for Hub-Specific Requests

 

Recipient

Value

Index

 

 

 

 

 

 

 

 

C_HUB_LOCAL_POWER

hub

00h

00h

 

 

 

 

C_HUB_OVER_CURRENT

hub

01h

00h

 

 

 

 