Virtuoso Schematic Composer User Guide

Understanding Connectivity and Naming Conventions

Connectivity with Objects

Connectivity is the logical connection between signals in a design. Connectivity is derived

(extracted) from the physical connections found in a schematic. Pins and wires implement physical connections. Terminals and signals implement logical connections. Pins and terminals indicate which signals in a cellview are imported from or exported to other levels of a design hierarchy.

A complete schematic design provides input data for a variety of design tools, such as simulation and layout. It is essential, therefore, that you establish connectivity in your schematic designs.

The following diagram shows connectivity and naming conventions.

A

 

 

 

 

 

H

B

reset

RESET

_

out<3:0>

 

I

 

 

Q

 

 

 

C

 

 

 

3

out<2>

J

 

clk

 

 

 

CLK

BUFF

 

 

K

 

 

 

 

INPUT

wire1

 

 

a0,a1,a2,a3

 

 

 

DATA

Q

 

 

 

 

 

ADDER

 

 

 

 

 

 

 

 

 

 

 

 

A<0:3>

 

D

 

 

 

 

 

L

E

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

[@ground:%:gnd!]

 

F

 

 

 

 

 

 

 

 

 

 

gnd!

 

M

G

 

 

 

 

 

 

Key

Connectivity / Name

Key

Connectivity / Name

 

 

 

 

A

Instance name

H

Overbars in a name

B

Single wire names

I

Wire name with multiple bits

C

Pin name

J

Bus tap

D

Wire-to-pin connection

K

Multiple-bit naming convention

October 2002

86

Product Version 5.0