16-60 ELECTRICAL SYSTEM

Lighting System

Insert the new bulb [A] by aligning its upper and lower pins [B] with the upper and lower grooves [C] in the socket, and turn the bulb clockwise.

TurnSignal Relay Inspection

Remove:

Seats (see Frame chapter)

Upper Seat Cover (see Frame chapter)

Turn Signal Relay [A]

Connect one 12 V battery and turn signal lights as indicated in the figure, and count how may times the lights flash for one minute.

Turn Signal Relay [A] Turn Signal Lights [B] 12 V Battery [C]

If the lights do not flash as specified, replace the turn signal relay.

Testing Turn Signal Relay

Load

 

 

Flashing times

 

 

 

The Number of Turn

 

 

Wattage (W)

(c/m*)

Signal Lights

 

 

 

 

 

 

 

1**

21

or 23

140 – 250

 

 

 

 

2

42

or 46

75 – 95

(*): Cycle(s) per minute

(**): Corrected to “one light burned out”.

Tail/BrakeLight (LED) Removal

Remove:

Seats (see Frame chapter)

Upper Seat Cover (see Frame chapter)

Disconnect the tail/brake light (LED) connectors [A] and

rear turn signal connectors [B]. Open the clamp [C].

ELECTRICAL SYSTEM 16-61

Lighting System

Unscrew the bolts [A].

Unscrew the mounting screws [A].

Remove the tail/brake light (LED) [B]. Pull out the mount portion [C].

Tail/BrakeLight (LED) Installation

Tighten the tail/brake light mounting screws.

Torque - Tail/Brake Light Mounting Screws: 1.2 N·m (0.12

kgf·m, 10 in·lb)

16-62 ELECTRICAL SYSTEM

Radiator Fan System

FanSystem Circuit Inspection

Disconnect the lead connector [A] from the radiator fan switch.

Usingleads.an auxiliary wire [A], connect the radiator fan switch If the fan rotates, inspect the fan switch.

If the fan does not rotate, inspect the following. Leads and Connectors

Main Fuse and Fan Fuse Fan Motor

FanMotor Inspection

Remove the fuel tank (see Fuel System (DFI) chapter). Disconnect the 2-pin connector [A] in the fan motor leads.

Pull the lead until come out the connector.

Using two auxiliary wires [A], supply battery [B] power to the fan motor.

If the fan does not rotate, the fan motor is defective and must be replaced.