Humidity control

Refrigeration air conditioning equipment usually reduces the humidity of the air processed by the system. The relatively cold (below the dewpoint) evaporator coil condenses water vapor from the processed air, (much like an ice-cold drink will condense water on the outside of a glass), sending the water to a drain and removing water vapor from the cooled space and lowering the relative humidity. Since humans perspire to provide natural cooling by the evaporation of perspiration from the skin, drier air (up to a point) improves the comfort provided. The comfort air conditioner is designed to create a 40% to 60% relative humidity in the occupied space. In food retailing establishments large open chiller cabinets act as highly effective air dehumidifying units.

A specific type of air conditioner that is used only for dehumidifying is called a dehumidifier. A dehumidifier is different from a regular air conditioner in that both the evaporator and condensor coils are placed in the same air path, and the entire unit is placed in the environment that is intended to be conditioned (in this case dehumidified), rather than requiring the condensor coil to be outdoors. Having the condensor coil in the same air path as the evaporator coil produces warm, dehumidified air. The evaporator (cold) coil is placed first in the air path, dehumidifying the air exactly as a regular air conditioner does. The air next passes over the condensor coil re-warming the now dehumidified air. Note that the terms "condensor coil" and "evaporator coil" do not refer to the behavior of water in the air as it passes over each coil; instead they refer to the phases of the refrigeration cycle. Having the condensor coil in the main air path rather than in a separate, outdoor air path (as in a regular air conditioner) results in two consequenses-- the output air is warm rather than cold, and the unit is able to be placed anywhere in the environment to be conditioned, without a need to have the condensor outdoors.

Ironically, unlike a regular air conditioner, a dehumidifier will actually heat a room just as an electric heater that draws the same amount of electricity (watts) as the dehumidifier. A regular air conditioner transfers energy out of the room by means of the condensor coil, which is outside the room (outdoors). This is a thermodynamic system where the room serves as the system and energy is transferred out of the system. Conversely with a dehumidifier, no energy is transferred out of the thermodynamic system (room) because the air conditioning unit (dehumidifier) is entirely inside the room. Therefore all of the electricity that is consumed by the dehumidifier is energy that is input into the thermodynamic system (the room), and remains in the room (as heat).

Dehumidifiers are commonly used in cold, damp climates to prevent mold growth indoors, especially in basements. They are also sometimes used in hot, humid climates for comfort because they reduce the humidity which causes discomfort (just as a regular air conditioner, but without cooling the room).