- •Scientific Papers
- •Scientific Papers
- •Scientific Papers
- •Scientific Papers
- •Scientific Papers
- •Legal Aspects
- •Foreign Collaborators
- •Legal Aspects
- •Foreign Collaborators
- •Contributors
- •Foreign Collaborators
- •Scientific Papers
- •Scientific Papers
- •Foreign Collaborators
- •I.A.Sokolov, and s.I.Stepanov, “Non-steady photovoltage in crystals with long relaxation time of photoconductivity,” Electron.Lett., V.26, pp. 1275-1277 (1990).
- •Foreign Collaborators
- •Foreign Collaborators
- •Scientific Papers
- •Foreign Collaborators
Foreign Collaborators
The close collaboration in the frame of ITER Design Task "Evaluation of ITER Disruption Erosion" could be possible with:
SANDIA National Labs, Albuquerque, USA (Drs. P.D. Rockett, et al.)
Argonne National Labs, USA (Dr. A. Hassanein)
Forschungszentrum Juelich, EURATOM-Association, Germany (Drs. J. Linke, H. Bolt)
Forschungszentrum Karlsruhe, Germany (Dr. H. Wuerz)
№-0131 High-Power Protective Circuit Breakers |
Full Title: |
High-Power Protective Circuit Breakers and Make Switches |
Technology Field(s): |
FUS-OTH: Fusion / Other NNE-EPP: Non-Nuclear Energy / Electric Power Production OTH-ELE: Other / Electrotechnology |
Contributors
Vladimir Kuchinski |
Efremov Scientific Research Institute of Electrophysical Apparatus (NIIEFA Efremov) 1, Sovetskiy pr., Metellostroj, St Petersburg, 189631, Russia Phone: 7+812+4627767; 7+812+2655991 Fax: 7+812+4644623; 7+812+4639812; 7+812+3143360 filatov@niiefa.spb.su |
Nikolai Mikhailov |
Efremov Scientific Research Institute of Electrophysical Apparatus (NIIEFA Efremov) 1, Sovetskiy pr., Metellostroj, St Petersburg, 189631, Russia Phone: 7+812+4627986; 7+812+2655991 Fax: 7+812+4644623; 7+812+4639812; 7+812+3143360 filatov@niiefa.spb.su |
|
|
Present Status of Research
Brief Description of Research
Experimental models have been developed and tested of the high-power protective circuit breakers and make switches that can operate with continuous currents of up to 60 kA, and at a voltage of 20 kV. The advantage of this unique equipment rests in the possibility of operating it quickly with large, steady-state currents of up to 60 kA. Such equipment is not available elsewhere in the world market. Moreover, it may be used in Power Supplies at different electrophysical and industrial installations (i.e. controlled fusion applications).
Legal Aspects
Results of the investigation of the protective switching equipment have been presented in a number of international conferences. Patent applications for some of this equipment have been approved in Russia.
Special Facilities
Some special facilities at the Efremov Institute have been used during the testing and investigation of the protective switching equipment, including: a 40 MJ homopolar generator that can produce pulsed currents of up to 1 MA with a duration of several seconds or more; a 5 MJ inductive energy storage with a rated current of 100 kA; a 2 MJ capacitor energy storage to generate large pulsed currents.
Scientific Papers
V. Kuchinski, B. Larionov, N. Mikhailov, S. Pavluk, A. Roshal, V. Risev, S. Uralov, “Switching Devices for the ITER Magnet Power Supply System,” Fusion Engineering and Design, 24, pp. 419-424 (1994).
V. Kuchinski, N. Mikhailov, V. Soikin, “High-Power Fast Switches,” Proceedings of 1995 International Power Electronics Conference (IPEC - Yokohama ‘95, Pacific Convention Plaza, Yokohama, Japan, pp. 899-903 (April 3-7, 1995).
V. Kuchinski, B. Larionov ,N. Mikhailov, V. Silin, V. Soikin, “High-Power Switches for the Inductive Energy Storage,” Tenth IEEE International Pulsed Power Conference, Abstract Book, Albuquerque, NM, USA, pp.2-40 (July, 1995).