KZTMBH12-LLD (1)
.pdfЗАО «AMT ГРУП» |
АО «Казахтелеком» |
fi echo 0 >/selinux/enforce
case "$1" in
'start') # Start the Oracle databases and listeners
su - $ORACLE_OWNER -c "$SHELL $ORACLE_HOME/bin/dbstart
$ORACLE_HOME"
if [ "$OS" = "Linux" ] ; then touch /var/lock/subsys/dbora
fi
;;
'stop') # Stop the Oracle databases and listeners
su - $ORACLE_OWNER -c "$SHELL $ORACLE_HOME/bin/dbshut
$ORACLE_HOME"
if [ "$OS" = "Linux" ] ; then
rm -f /var/lock/subsys/dbora
fi
;;
esac
Скрипты автозапуска Prime Performance Manager
/etc/init.d/ppm.gw
#!/bin/sh
exec /opt/CSCOppm-gw/bin/ppm $@
/etc/init.d/ppm.unit
#!/bin/sh
exec /opt/CSCOppm-unit/bin/ppm $@
Скрипты автозапуска Prime Provisioning
/etc/init.d/PrimeProvisioning
#!/bin/sh
OWNER=iscadm PRIMEF_HOME=/opt/PrimeProvisioning
. $PRIMEF_HOME/bin/vpnenv.sh
stop_primef() {
su $OWNER -c ". $PRIMEF_HOME/bin/vpnenv.sh; $PRIMEF_HOME/bin/stopall > /dev/null 2>&1"
isc_rc=$?
if [ $isc_rc -ne 0 ]; then
echo "$0: Error ${isc_rc} stopping Cisco Prime Provisioning ..." exit $isc_rc
fi
echo done.
}
start_primef() {
su $OWNER -c ". $PRIMEF_HOME/bin/vpnenv.sh; $PRIMEF_HOME/bin/startwd > /dev/null 2>&1"
isc_rc=$?
if [ $isc_rc -ne 0 ]; then
echo "$0: Error ${isc_rc} starting Cisco Prime Provisioning ...
bailing."
exit $isc_rc
fi
echo done.
}
case $1 in
KZTMBH12 |
241 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
|
|
'start') start_primef
;;
'stop') stop_primef
;;
'restart') stop_primef start_primef
;;
*) "$0: usage: $0 {start|stop|restart}"
;;
esac
KZTMBH12 |
242 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
|
|
ПРИЛОЖЕНИЕ Ж. ПЕРЕЧЕНЬ ПОДДЕРЖИВАЕМЫХ SNMP MIB
ASR-903
BGP4-MIB BRIDGE-MIB
CISCO-ACCESS-ENVMON-MIB CISCO-CAR-MIB CISCO-CDP-MIB CISCO-CEF-MIB CISCO-CLASS-BASED-QOS-MIB CISCO-CONFIG-COPY-MIB CISCO-CONFIG-MAN-MIB CISCO-DATA-COLLECTION-MIB CISCO-DOT3-OAM-MIB CISCO-EIGRP-MIB
CISCO-ENHANCED-MEMPOOL-MIB CISCO-ENTITY-ASSET-MIB CISCO-ENTITY-VENDORTYPE-OID-MIB CISCO-ENVMON-MIB CISCO-FLASH-MIB CISCO-IETF-BFD-MIB CISCO-IETF-PW-MIB CISCO-IETF-PW-TC-MIB CISCO-IF-EXTENSION-MIB CISCO-IMAGE-MIB CISCO-IPSLA-ETHERNET-MIB CISCO-MEMORY-POOL-MIB CISCO-NETSYNC-MIB
CISCO-NTP-MIB
CISCO-OSPF-MIB
CISCO-PING-MIB CISCO-PROCESS-MIB CISCO-PRODUCTS-MIB CISCO-PTP-MIB CISCO-QUEUE-MIB
CISCO-RESILIENT-ETHERNET-PROTOCOL-MIB CISCO-RTTMON-MIB
CISCO-SMI-MIB
ASR-901 И
KZTMBH12 |
243 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
CISCO-SNAPSHOT-MIB
CISCO-SNMP-TARGET-EXT-MIB
CISCO-STP-EXTENSIONS-MIB
CISCO-SYSLOG-MIB
CISCO-TC-MIB
ENTITY-MIB
ETHERLIKE-MIB
HCNUM-TC
IANAIFTYPE-MIB
IEEE8021-CFM-MIB
IF-MIB
IMA-MIB
INT-SERV-MIB
IP-FORWARD-MIB
IP-MIB
MPLS-LDP-MIB
MPLS-LSR-MIB
MPLS-VPN-MIB
NOTIFICATION-LOG-MIB
OLD-CISCO-CHASSIS-MIB
OLD-CISCO-FLASH-MIB
OLD-CISCO-INTERFACES-MIB
OLD-CISCO-IP-MIB
OLD-CISCO-SYS-MIB
OLD-CISCO-TS-MIB
OSPF-MIB
PERFHIST-TC-MIB
RFC1213-MIB
RMON-MIB
RMON2-MIB
SNMP-FRAMEWORK-MIB
SNMP-TARGET-MIB
SNMPv2-MIB
SNMPv2-SMI
SNMPv2-TC-MIB
TCP-MIB
UDP-MIB
KZTMBH12 |
244 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
|
|
ПРИЛОЖЕНИЕ З. ПЕРЕЧЕНЬ
ПОДДЕРЖИВАЕМЫХ SNMP MIB ASR-9010
ATM-MIB ATM-FORUM-MIB ATM2-MIB BGP4-MIB BRIDGE-MIB CISCO-ATM-EXT-MIB CISCO-ATM-QOS-MIB CISCO-BGP4-MIB
CISCO-BGP-POLICY-ACCOUNTING-MIB CISCO-BULK-FILE-MIB CISCO-CDP-MIB CISCO-CLASS-BASED-QOS-MIB CISCO-CONFIG-COPY-MIB CISCO-CONFIG-MAN-MIB CISCO-CONTEXT-MAPPING-MIB CISCO-DS3-MIB CISCO-ENHANCED-IMAGE-MIB CISCO-ENHANCED-MEMPOOL-MIB CISCO-ENTITY-ASSET-MIB CISCO-ENTITY-FRU-CONTROL-MIB CISCO-ENTITY-REDUNDANCY-MIB CISCO-ENTITY-SENSOR-MIB CISCO-ENTITY-STATE-EXT-MIB CISCO-FLASH-MIB CISCO-FLOW-CLONE-MIB CISCO-FLOW-MONITOR-MIB CISCO-FRAME-RELAY-MIB CISCO-FTP-CLIENT-MIB CISCO-HSRP-EXT-MIB CISCO-HSRP-MIB CISCO-IETF-BFD-MIB CISCO-IETF-FRR-MIB CISCO-IETF-MPLS-TE-P2MP-STD-MIB CISCO-IETF-IPMROUTE-MIB CISCO-IETF-MSDP-MIB CISCO-IETF-PIM-MIB
KZTMBH12 |
245 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
CISCO-IETF-PIM-EXT-MIB
CISCO-IETF-PW-ENET-MIB
CISCO-IETF-PW-MIB
CISCO-IETF-PW-FR-MIB
CISCO-IETF-PW-MPLS-MIB
CISCO-IETF-PW-TC-MIB
CISCO-IETF-VPLS-BGP-EXT-MIB
CISCO-IETF-VPLS-GENERIC-MIB
CISCO-IETF-VPLS-LDP-MIB
CISCO-IF-EXTENSION-MIB
CISCO-IP-CBR-METRICS-MIB
CISCO-IP-TAP-MIB
CISCO-IP-STAT-MIB
CISCO-IPSEC-MIB
CISCO-IPSEC-FLOW-MONITOR-MIB
CISCO-LICENSE-MGMT-MIB
CISCO-MEMORY-POOL-MIB
CISCO-MLD-SNOOPING-MIB
CISCO-NTP-MIB
CISCO-OAM-MIB
CISCO-OTN-IF-MIB
CISCO-P2P-IF-MIB
CISCO-PIM-MIB
CISCO-PING-MIB
CISCO-PROCESS-MIB
CISCO-RF-MIB
CISCO-RTTMON-MIB
CISCO-SELECTIVE-VRF-DOWNLOAD-MIB
CISCO-SONET-MIB
CISCO-SYSLOG-MIB
CISCO-SYSTEM-MIB
CISCO-TAP2-MIB
CISCO-TCP-MIB
CISCO-VLAN-IFTABLE-RELATIONSHIP-MIB
DISMAN-EXPRESSION-MIB
DOT3-OAM-MIB
DS1-MIB (RFC 2495)
DS3-MIB
ENTITY-MIB (RFC 2737)
ENTITY-STATE-MIB
KZTMBH12 |
246 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
ETHERLIKE-MIB (RFC 2665, 3635)
EVENT-MIB
EXPRESSION-MIB
FRAME-RELAY-DTE-MIB
IEEE8021-CFM-MIB
IEEE8023-LAG-MIB
IETF-TCP-MIB
IETF-UDP-MIB
IF-MIB (RFC 2863)
IMA-MIB
IP-FORWARD-MIB
IP-MIB
IPV6-MIB
IPV6-FORWARD-MIB
IPV6-MLD-MIB
IPV6-TC
ISIS-MIB
MAU-MIB
MFR-MIB
MGMD-STD-MIB
MPLS-L3VPN-STD-MIB
MPLS-LDP-GENERIC-STD-MIB
MPLS-LDP-STD-MIB
MPLS-LSR-STD-MIB
MPLS-TC-STD-MIB
MPLS-TE-STD-MIB
NOTIFICATION-LOG-MIB
OSPF-MIB
OSPF-TRAP-MIB
OSPFV3-MIB
PIM-MIB
RADIUS-ACC-CLIENT-MIB
RADIUS-AUTH-CLIENT-MIB
RFC1213-MIB
RFC 2011-MIB
RFC 2465-MIB
RSVP-MIB
SNMP-COMMUNITY-MIB (RFC 2576)
SNMP-FRAMEWORK-MIB (RFC 2571)
SNMP-NOTIFICATION-MIB (RFC 2573)
KZTMBH12 |
247 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
SNMP-TARGET-MIB (RFC 2573)
SNMP-USM-MIB (RFC 2574)
SNMPv2-MIB (RFC 1907)
SNMP-VACM-MIB
SONET-MIB (RFC 2558)
TCP-MIB
UDP-MIB
VRRP-MIB
KZTMBH12 |
248 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
|
|
ПРИЛОЖЕНИЕ И. ПЕРЕЧЕНЬ ПОДДЕРЖИВАЕМЫХ SNMPV3 TRAPS ASR 901
И 903
Cisco IOS V2/V3 Traps для устройств ASR 901 и 903
|
|
Subtype |
Subtype |
|
|
|
Varbind |
|
|
Trap Name |
Trap OID |
Varbind OID |
Value |
Description |
|
|
|
|
|
cbfDefineFileCompletion |
1.3.6.1.4.1.9.9.81.2.0.1 |
N/A |
N/A |
A cbfDefineFileCompletion notification is sent on the |
|
|
|
|
following conditions: completion of a file consumption |
|
|
|
|
operation in case of ephemeral files: completion of file |
|
|
|
|
creation operation in case of volatile or permanent files: |
|
|
|
|
any error during file creation. |
|
|
|
|
|
cbgpBackwardTransition |
1.3.6.1.4.1.9.9.187.0.2 |
1.3.6.1.4.1.9.9.187.0.2 |
!= (1or 6) |
The cbgpBackwardTransition Event is generated when |
|
|
|
|
the BGP FSM moves from a higher numbered state to a |
|
|
|
|
lower numbered state. The bgpPeerRemoteAddr value |
|
|
|
|
is attached to the notification Object Identifier. |
|
|
|
|
|
cbgpFsmStateChange |
1.3.6.1.4.1.9.9.187.0.1 |
1.3.6.1.4.1.9.9.187.0.2 |
= 1 |
The BGP cbgpFsmStateChange notification is generated |
|
|
|
|
for every BGP FSM state change. |
|
|
|
|
|
cbgpFsmStateChange |
1.3.6.1.4.1.9.9.187.0.1 |
1.3.6.1.4.1.9.9.187.0.2 |
= 6 |
The BGP cbgpFsmStateChange notification is generated |
|
|
|
|
for every BGP FSM state change. |
|
|
|
|
|
cbgpPrefixThresholdExceeded |
1.3.6.1.4.1.9.9.187.0.3 |
N/A |
N/A |
The cbgpPrfefixMaxThresholdExceeded notification is |
|
|
|
|
generated when prefix count exceeds the configured |
|
|
|
|
warning threshold on a session for an address family |
|
|
|
|
|
cbgpPrefixThresholdClear |
1.3.6.1.4.1.9.9.187.0.4 |
N/A |
N/A |
The cbgpPrefixThresholdClear notification is generated |
|
|
|
|
when prefix count drops below the configured clear |
|
|
|
|
threshold on a session for an address family once |
|
|
|
|
cbgpPrefixThresholdExceeded is generated. This won't |
|
|
|
|
be generated if the peer session goes down after the |
|
|
|
|
generation of bgpPrefixThresholdExceeded. The |
|
|
|
|
bgpPeerRemoteAddr, bgpPeerAddrFamilyAfi and |
|
|
|
|
cbgpPeerAddrFamilySafi values are attached to the |
|
|
|
|
notification Object Identifier. |
|
|
|
|
|
Short Description
CBF File operation state indicator
Cisco BGP backward transition trap
Cisco BGP down trap
Cisco BGP established trap
Cisco BGP prefix threshold exceeded
Cisco BGP prefix threshold clear
KZTMBH12 |
249 |
Технический проект |
ЗАО «AMT ГРУП» |
АО «Казахтелеком» |
|
|
|
Subtype |
|
|
|
Subtype |
Varbind |
|
Trap Name |
Trap OID |
Varbind OID |
Value |
Description |
|
|
|
|
|
ccCopyCompletion |
1.3.6.1.4.1.9.9.96.2.1.1 |
N/A |
N/A |
A ccCopyCompletion trap is sent at the completion of a |
|
|
|
|
config copy request. The ccCopyFailCause is not |
|
|
|
|
instantiated, and hence not included in a trap, when the |
|
|
|
|
ccCopyState is success |
|
|
|
|
|
ciscoConfigManEvent |
1.3.6.1.4.1.9.9.43.2.0.1 |
N/A |
N/A |
Notification of a configuration management event as |
|
|
|
|
recorded in ccmHistoryEventTable. |
|
|
|
|
|
cefcFanTrayStatusChange |
1.3.6.1.4.1.9.9.117.2.0.6 |
1.3.6.1.4.1.9.9.117.1.4.1.1.1 |
!=2 |
This notification is generated when the value of |
|
|
|
|
cefcFanTrayOperStatus changes. |
|
|
|
|
|
cefcFanTrayStatusChange |
1.3.6.1.4.1.9.9.117.2.0.6 |
1.3.6.1.4.1.9.9.117.1.4.1.1.1 |
=2 |
This notification is generated when the value of |
|
|
|
|
cefcFanTrayOperStatus changes. |
|
|
|
|
|
cefcFRUInserted |
1.3.6.1.4.1.9.9.117.2.0.3 |
N/A |
N/A |
The cecfFRUInserted notification indicates that a FRU |
|
|
|
|
was inserted. The varbind for this notification indicates |
|
|
|
|
the entPhysicalIndex of the inserted FRU, and the |
|
|
|
|
entPhysicalIndex of the FRU's container. |
|
|
|
|
|
cefcFRURemoved |
1.3.6.1.4.1.9.9.117.2.0.4 |
N/A |
N/A |
The cefcFRURemoved notification indicates that a FRU |
|
|
|
|
was removed. The varbind for this notification indicates |
|
|
|
|
the entPhysicalIndex of the removed FRU, and the |
|
|
|
|
entPhysicalIndex of the FRU's container. |
|
|
|
|
|
cefcModuleStatusChange |
1.3.6.1.4.1.9.9.117.2.0.1 |
1.3.6.1.4.1.9.9.117.1.2.1.1.2 |
!=2 |
This notification is generated when the value of |
|
|
|
|
cefcModuleOperStatus changes. It can be utilized by an |
|
|
|
|
NMS to update the status of the module it is managing. |
|
|
|
|
|
cefcModuleStatusChange |
1.3.6.1.4.1.9.9.117.2.0.1 |
1.3.6.1.4.1.9.9.117.1.2.1.1.2 |
=2 |
This notification is generated when the value of |
|
|
|
|
cefcModuleOperStatus changes. It can be utilized by an |
|
|
|
|
NMS to update the status of the module it is managing. |
|
|
|
|
|
cefcPowerStatusChange |
1.3.6.1.4.1.9.9.117.2.0.2 |
1.3.6.1.4.1.9.9.117.1.1.2.1.2 |
!=2 |
The cefcFRUPowerStatusChange notification indicates |
|
|
|
|
that the power status of a FRU has changed. The |
|
|
|
|
varbind for this notification indicates the |
|
|
|
|
entPhysicalIndex of the FRU, and the new operational |
|
|
|
|
status of the FRU. |
|
|
|
|
|
Short Description
Config copy request completion
Cisco Configuration management event notification
cefc fan tray oper status down
cefc fan tray oper status up
cefc FRU inserted
cefc FRU removed
cefc module oper status down
cefc module oper status up
cefc power status down
KZTMBH12 |
250 |
Технический проект |